Dental Compressor Control Panel
Dental Equipment

Dental Compressor Control Retrofit

A dental clinic's 15-year-old air compressor had a proprietary control board that was no longer available. Rather than replacing the entire compressor system (quoted at over $12,000), we reverse-engineered the control logic and designed a modern replacement using off-the-shelf components.

Challenge

Obsolete control board with no replacement parts available. Original manufacturer no longer supporting the model.

Solution

  • Reverse-engineered existing control logic
  • Designed custom control panel using current components
  • Integrated pressure monitoring and motor protection
  • Added improved diagnostics and status indication

Outcome

Compressor back in service at approximately 25% of replacement cost. Client now has documentation and readily available spare parts for future maintenance.

Commercial Conveyor Oven
Restaurant Equipment

Commercial Oven Temperature Control Repair

A high-volume restaurant's conveyor oven was experiencing erratic temperature control, affecting food quality and production times. The original control system had multiple failing components.

Challenge

Intermittent temperature swings causing inconsistent cooking. Multiple service calls from other technicians had not resolved the issue.

Solution

  • Systematic troubleshooting of heating circuits and controls
  • Replaced failing SSR and temperature controller
  • Repaired damaged wiring and connections
  • Calibrated temperature setpoints and tuned control response

Outcome

Oven returned to stable operation with precise temperature control. Provided preventive maintenance recommendations to avoid future issues.

Walk-in Freezer Control System
Refrigeration

Walk-in Freezer Control System Troubleshooting

A restaurant's walk-in freezer was experiencing frequent defrost cycles and temperature fluctuations, risking product loss and health code violations.

Challenge

Freezer not maintaining temperature. Defrost timer running too frequently. Previous diagnosis suggested replacing the entire refrigeration system.

Solution

  • Identified failed defrost termination thermostat
  • Discovered incorrect defrost timer settings
  • Repaired damaged evaporator fan wiring
  • Reprogrammed defrost schedule for actual usage patterns

Outcome

Freezer operating properly with correct defrost cycling. Total repair cost under $500 versus $15,000+ for unnecessary refrigeration replacement.

Restaurant Electrical Design
Electrical Engineering

Restaurant Tenant Fit-Out - Electrical Design

Complete electrical design for a new restaurant build-out in an existing commercial building. Worked with the electrical contractor and building management to deliver code-compliant, permit-ready drawings.

Scope

  • Electrical load calculations for commercial kitchen equipment
  • Power distribution design and panel schedules
  • Dedicated circuits for kitchen equipment (ovens, fryers, steamers, etc.)
  • Lighting layout for dining and kitchen areas
  • Emergency lighting and exit signs
  • HVAC equipment power connections

Deliverables

Complete electrical drawings stamped by licensed engineer, approved by ESA for permit. Contractor feedback confirmed designs were clear and practical to install.

HVAC Control Panel
Electrical Engineering

Custom Control Panel - HVAC Application

Designed a custom control panel for a multi-zone HVAC system in a commercial building. Panel integrated with building management system and provided local control capabilities.

Design Elements

  • Single-line and schematic diagrams
  • Motor starters for HVAC fans and pumps
  • VFD integration for variable speed control
  • Temperature and pressure monitoring
  • Safety interlocks and alarm outputs
  • Communication interface to BMS

Deliverables

Complete electrical design documentation including schematics, panel layout, wire lists, and bill of materials. Panel fabricated by local shop and commissioned successfully.

Dental Vacuum System
Dental Equipment

Dental Vacuum System Upgrade

A dental practice's vacuum system had a failing control board with no available replacement. We designed and installed a modern control system with improved reliability and diagnostics.

Challenge

20-year-old vacuum system with proprietary controls. Manufacturer out of business, no parts or service available.

Solution

  • Analyzed existing system operation and control requirements
  • Designed new control panel with modern components
  • Implemented automatic and manual operating modes
  • Added remote monitoring and diagnostic features
  • Provided complete documentation for future service

Outcome

Vacuum system operating reliably with improved performance. Practice avoided costly replacement and has serviceable system with available parts.

Commercial Dishwasher
Restaurant Equipment

Commercial Dishwasher Electrical Troubleshooting

High-temperature dishwasher intermittently tripping circuit breakers during wash cycles, causing operational disruptions during peak service hours.

Challenge

Intermittent circuit breaker trips with no obvious pattern. Multiple service calls had not identified root cause.

Solution

  • Performed systematic electrical load testing during all operating modes
  • Identified failing contactor causing current spikes
  • Discovered loose connection in heating element circuit
  • Replaced faulty components and secured all connections
  • Verified proper operation under full load conditions

Outcome

Dishwasher operating reliably with no further trips. Restaurant able to maintain service during all operating hours.

Electrical Documentation
Electrical Engineering

As-Built Electrical Documentation - Commercial Kitchen

Created comprehensive as-built electrical documentation for a commercial kitchen that had undergone multiple renovations over the years with no current drawings.

Scope

  • Field verification of all electrical panels and circuits
  • Documentation of equipment connections and ratings
  • Panel schedule updates with accurate circuit identification
  • Single-line diagram of power distribution
  • Equipment layout with circuit assignments

Outcome

Complete, accurate electrical documentation for facility management. Drawings used for subsequent renovation planning and contractor bidding.

Commercial Gas Range
Restaurant Equipment

Commercial Gas Range Ignition System Repair

Restaurant gas range with multiple burners experiencing ignition failures and safety lockouts, affecting kitchen operations.

Challenge

Burners not igniting consistently. Flame safety system triggering lockouts. Gas flow issues on several burners.

Solution

  • Cleaned and adjusted burner orifices and pilots
  • Replaced failed flame sensors and ignition modules
  • Adjusted gas pressure and air mixture
  • Tested and verified all safety interlocks
  • Performed leak check on all gas connections

Outcome

All burners igniting reliably with proper flame characteristics. Safety systems functioning correctly. Kitchen back to full operation.

About These Projects

The projects shown represent the types of work we regularly perform. Specific client names and proprietary details are not disclosed to respect confidentiality agreements. All work is performed in accordance with applicable codes and standards, and engineering projects are sealed by a licensed engineer when required.

Every situation is different. While these examples show our experience and approach, your specific project will receive individual attention and custom solutions tailored to your needs.

Have a Project or Repair Need?

Contact us to discuss your specific situation and how we can help.

Get in Touch